Description: Regi Sensor/Fusing Unit Exit Sensor/ Feed Out Sensor 2 Static Jam Paper was detected by the applicable sensor at Power ON, M/C Stop, or Interlock Close.
Remedy: 1. Check the applicable sensor for remaining paper, the Actuator for return failure, contamination on sensor, and etc. 2. Check the applicable sensor for operation failure. • Regi Sensor (Input Check[071-105]) (PL 15.1) • Fusing Unit Exit Sensor (Input Check[071-106]) (PL 7.1) • Feed Out Sensor 2 (Input Check[072-104]) (PL 10.5) 3. If no problem is found, replace the following parts: • ESS/MCU PWB (Regi Sensor, Fusing Unit Exit Sensor) (PL 18.1) • STM PWB (Feed Out Sensor 2) (PL 10.6)