Description: Tray 3 Paper Size Switch Broken The Tray 3 Size Sensor open circuit was detected. (The AD value is at its largest.) NOTE: If this is already detected, it will be displayed on the UI Panel when a Job is being performed
Remedy: Check the following: • The connection between the Tray 3 Paper Size Switch J820 and the 2TM PWB J548 for open circuit, short circuit, and poor contact. • Tray 3 Paper Size Switch: Analog Monitor [072-052]/Input Check [072-110] (PL 11.1) • The Tray 3 paper guide mechanism for damage and foreign substances. • The Tray 3 Paper Size Switch for damage, improper installation, and Actuator operation failure. If no problems are found, replace the 2TM PWB (PL 11.6).