Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 010-320 — Xerox WorkCentre 5022

Code: 010-320

Description: Over Heat Temperature Fail A high temperature error was detected at the Center Thermistor (245 degrees C or higher) or the Rear Thermistor (270 degrees C or higher). NOTE: To clear this Fail, first remove the cause, next clear the value of NVM [744-040] (Over Heat Temp Fail) to '0', and then turn the power OFF then ON. The relationship between the displayed value and the Thermistor that detected the high temperature error is as follows: • 0: Normal • 1: High Temperature Error of Heat Roll Center Thermistor • 2: High Temperature Error of Heat Roll Rear Thermistor
Remedy: Check the following: • The Center Thermistor or the Rear Thermistor for dropped parts, sensor contamination, and foreign substances blocking the sensor. • The Heat Roll for wound up, stuck paper. • The Heat Roll Center Thermistor (Analog Monitor [010-050]) for operation failure. • The Heat Roll Rear Thermistor (Analog Monitor [010-051]) for operation failure. • The Heater Rod for operation failure. If no problem is found, replace the following parts in sequence: • Fusing Unit (PL 7.1) • LVPS (PL 18.3) • ESS/MCU PWB (PL 18.3)

← Xem tất cả mã lỗi Xerox WorkCentre 5022