Code: 042-325, 042-614
Description: Main Motor Rotation Error/ Main Motor Rotation Warning [Main Motor Rotation Error] The Main Drive Motor revolution failure was detected. When the Lock Up (Main Drive Motor Fail) signal of the Motor Drive output was monitored at the specified time interval after a certain time has passed since the Main Drive Motor operation had started, it was found to have failed 5 times in a row. [Main Motor Rotation Warning] The Main Drive Motor revolution failure was detected. When the Lock Up (Main Drive Motor Fail) signal of the Motor Drive output was monitored at the specified time interval after a certain time has passed since the Main Drive Motor operation had started, it was found to have failed 2 times in a row.
Remedy: Enter the CE Mode and turn ON the Output Check [042-001] (Main Drive Motor). Does the Main Drive Motor rotate? Y↓N→Check the power supply line (+24VDC, +5VDC) of the Main Drive Motor. Is the power supply of the Main Drive Motor normal? Y↓N→Check the power supply circuit to the Main Drive Motor. Turn OFF the power and check the following: • The connection between the Main Drive Motor J202 and the ESS/MCU PWB J403 for open circuit, short circuit, and poor contact. • The Drive Gear for wear, damage, and bearing blockage. • The Main Drive Motor for loading. If no problem is found, replace the following parts in sequence: • Main Drive Motor (PL 3.1) • ESS/MCU PWB (PL 18.3) Press [Stop] and turn OFF the power. Check the connection between the Main Drive Motor J202-8 and the ESS/MCU PWB J403-5 for open circuit, short circuit, and poor contact. If no problem is found, replace the following parts in sequence: • ESS/MCU PWB (PL 18.3) • Main Drive Motor (PL 3.1)