Description: Carriage Position Fail Any of the following was detected: • An error with the count value of the Carriage Position Control. • There is no IIT Regi Sensor input during Carriage initialization. • An error with the IIT Regi Sensor detection position.
Remedy: Check the following: • The IIT Regi Sensor (Input Check [062-212]) for operation failure. (PL 1.9) • The Carriage Motor (Output Check [062-005/006] (Scan/Return)) for operation failure. (PL 1.9) • The Drive Belt and Drive Wire for slack and wear. • The Carriage operation for mechanical loading. If no problems are found, replace the ESS/MCU PWB. (PL 18.3)