Description: CVT Simplex/Side1 Pre-Registration On JAM RAP • After the Pre Feed operation started for the first sheet (DADF Feed Motor On (CW)) in Duplex or Simplex mode, the Pre-Registration Sensor did not turn On within the specified time. • After the Pre Feed operation started for the second sheet onwards (DADF Feed Motor On (CW)) in Duplex mode, the Pre-Registration Sensor did not turn On within the specified time
Remedy: Execute Component Control[005-206]. Actuate the DADF Pre Registration Sensor (PL 15.7) with paper. The display changes. Y↓N→Check the connections of P/J781 and P/J761. P/J781 and P/J761 are connected correctly. Y↓N→Connect P/J781 and P/J761. Check the wire between J781 and J761 for an open circuit or a short circuit. The wire between J781 and J761 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P761-10 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P761-12 (+) and GND (-). Actuate the DADF Pre Registration Sensor with paper. The voltage changes. Y↓N→Replace the DADF Pre Registration Sensor (PL 15.7). Replace the DADF PWB (PL 15.3). Execute Component Control[005-001]. The DADF Feed Motor (PL 15.9) starts up. Y↓N→Check the connections of P/J764 and P/J754. P/J764 and P/J754 are connected correctly. Y↓N→Connect P/J764 and P/J754. Check the wire between J764 and J754 for an open circuit or a short circuit. The wire between J764 and J754 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB (PL 15.3) P754-1 (+) and GND (-), and between P754-7 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the DADF PWB (PL 15.3). Replace the DADF Feed Motor (PL 15.9). If the problem persists, replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).