Code: 003-318

Description: IIT Soft Failure RAP The IIT software is faulty
Remedy: Check the P/Js on the IIT/IPS PWB (PL 11.3). If the problem persists, reload Firmware (ADJ 9.3.1).

Code: 003-319

Description: IIT Video Driver Detection Failure RAP A Compression Threshold overflow, DMA Transfer error, or Other compression system errors were detected.
Remedy: Check the P/Js on the IIT/IPS PWB (PL 11.3). If the problem persists, reload Firmware (ADJ 9.3.1).

Code: 003-320

Description: IISS-ESS Communication Failure 1 RAP An abnormal parameter is set for the send function.
Remedy: Check the P/Js on the IIT/IPS PWB (PL 11.3). Check the P/Js on ESS PWB (PL 9.2). If the problem persists, reload Firmware (ADJ 9.3.1).

Code: 005-121

Description: CVT Feed Sensor On JAM RAP After the first-out feed operation started (Feed Motor On (CW)) in Duplex mode, the DADF Feed Out Sensor did not turn On within the specified time.
Remedy: Execute Component Control[005-205]. Actuate the DADF Feed Out Sensor (PL 15.6) with paper. The display changes. Y↓N→Check the connections of P/J769 and P/J758. P/J769 and P/J758 are connected correctly. Y↓N→Connect P/J769 and P/J758. Check the wire between J769 and J758 for an open circuit or a short circuit. The wire between J769 and J758 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P758-1 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P758-3 (+) and GND (-). Actuate the DADF Feed Out Sensor with paper. The voltage changes. Y↓N→Replace the DADF Feed Out Sensor (PL 15.9). Replace the DADF PWB (PL 15.3). Execute Component Control[005-001]. The DADF Feed Motor (PL 15.9) starts up. Y↓N→Check the connections of P/J764 and P/J754. P/J764 and P/J754 are connected correctly. Y↓N→Connect P/J764 and P/J754. Check the wire between J764 and J754 for an open circuit or a short circuit. The wire between J764 and J754 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB (PL 15.3) P754-1 (+) and GND (-), and between P754-7 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the DADF PWB (PL 15.3). Replace the DADF Feed Motor (PL 15.9). If the problem persists, replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).

Code: 005-122

Description: CVT Simplex/Side1 Pre-Registration On JAM RAP • After the Pre Feed operation started for the first sheet (DADF Feed Motor On (CW)) in Duplex or Simplex mode, the Pre-Registration Sensor did not turn On within the specified time. • After the Pre Feed operation started for the second sheet onwards (DADF Feed Motor On (CW)) in Duplex mode, the Pre-Registration Sensor did not turn On within the specified time
Remedy: Execute Component Control[005-206]. Actuate the DADF Pre Registration Sensor (PL 15.7) with paper. The display changes. Y↓N→Check the connections of P/J781 and P/J761. P/J781 and P/J761 are connected correctly. Y↓N→Connect P/J781 and P/J761. Check the wire between J781 and J761 for an open circuit or a short circuit. The wire between J781 and J761 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P761-10 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P761-12 (+) and GND (-). Actuate the DADF Pre Registration Sensor with paper. The voltage changes. Y↓N→Replace the DADF Pre Registration Sensor (PL 15.7). Replace the DADF PWB (PL 15.3). Execute Component Control[005-001]. The DADF Feed Motor (PL 15.9) starts up. Y↓N→Check the connections of P/J764 and P/J754. P/J764 and P/J754 are connected correctly. Y↓N→Connect P/J764 and P/J754. Check the wire between J764 and J754 for an open circuit or a short circuit. The wire between J764 and J754 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB (PL 15.3) P754-1 (+) and GND (-), and between P754-7 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the DADF PWB (PL 15.3). Replace the DADF Feed Motor (PL 15.9). If the problem persists, replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).

Code: 005-123

Description: CVT Simplex/Side1 Registration JAM RAP After pre-registration started (DADF Feed Motor On (CCW)), the Registration Sensor did not turn On within the specified time.
Remedy: Execute Component Control[005-110]. Actuate the DADF Registration Sensor (PL 15.7) with paper. The display changes. Y↓N→Check the connections of P/J782 and P/J761. P/J782 and P/J761 are connected correctly. Y↓N→Connect P/J782 and P/J761. Check the wire between /J782 and J761 for an open circuit or a short circuit. The wire between /J782 and J761 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P761-15 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P761-14 (+) and GND (-). Actuate the DADF Registration Sensor with paper. The voltage changes. Y↓N→Replace the DADF Registration Sensor (PL 15.7). Replace the DADF PWB (PL 15.3). Execute Component Control[005-001]. The DADF Feed Motor (PL 15.9) starts up. Y↓N→Check the connections of P/J764 and P/J754. P/J764 and P/J754 are connected correctly. Y↓N→Connect P/J764 and P/J754. Check the wire between J764 and J754 for an open circuit or a short circuit. The wire between J764 and J754 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB (PL 15.3) P754-1 (+) and GND (-), and between P754-7 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the DADF PWB (PL 15.3). Replace the DADF Feed Motor (PL 15.9). If the problem persists, replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).

Code: 005-125

Description: CVT Registration Sensor Off JAM RAP After the Pre Registration Sensor turned Off during the Read operation, the DADF Registration Sensor did not turn Off within the specified time.
Remedy: Execute Component Control[005-110]. Actuate the DADF Registration Sensor (PL 15.7) with paper. The display changes. Y↓N→Check the connections of P/J782 and P/J761. P/J782 and P/J761 are connected correctly. Y↓N→Connect P/J782 and P/J761. Check the wire between J782 and J761 for an open circuit or a short circuit. The wire between J782 and J761 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P761-15 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P761-14 (+) and GND (-). Actuate the DADF Registration Sensor with paper. The voltage changes. Y↓N→Replace the DADF Registration Sensor (PL 15.7). Replace the DADF PWB (PL 15.3). Execute Component Control[005-001]. The DADF Feed Motor (PL 15.9) starts up. Y↓N→Check the connections of P/J764 and P/J754. P/J764 and P/J754 are connected correctly. Y↓N→Connect P/J764 and P/J754. Check the wire between J764 and J754 for an open circuit or a short circuit. The wire between J764 and J754 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB (PL 15.3) P754-1 (+) and GND (-), and between P754-7 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the DADF PWB (PL 15.3). Replace the DADF Feed Motor (PL 15.9). If the problem persists, replace the DADF PWB (PL 15.3). Execute Component Control[005-026]. The DADF Registration Motor (PL 15.9) starts up. Y↓N→Check the connections of P/J765 and P/J755. P/J765 and P/J755 are connected correctly. Y↓N→Connect P/J765 and P/J755. Check the wire between J765 and J755 for an open circuit or a short circuit. The wire between J765 and J755 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB (PL 15.3) P755-1 (+) and GND (-), and between P755-6 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the DADF PWB (PL 15.3). Replace the DADF Registration Motor (PL 15.9). If the problem persists, replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).

Code: 005-131

Description: CVT Invert On JAM RAP After the Registration Sensor turned On during Invert operation, the Invert Sensor did not turn On within the specified time.
Remedy: Execute Component Control[005-211]. Actuate the DADF Invert Sensor (PL 15.7) with paper. The display changes. Y↓N→Check the connections of P/J780 and P/J761. P/J780 and P/J761 are connected correctly. Y↓N→Connect P/J780 and P/J761. Check the wire between J780 and J761 for an open circuit or a short circuit. The wire between J780 and J761 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB P761-7 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the DADF PWB (PL 15.3). Measure the voltage between the DADF PWB P761-9 (+) and GND (-). Actuate the DADF Invert Sensor with paper. The voltage changes. Y↓N→Replace the DADF Invert Sensor (PL 15.7). Replace the DADF PWB (PL 15.3). Execute Component Control[005-026]. The DADF Registration Motor (PL 15.9) starts up. Y↓N→Check the connections of P/J765 and P/J755. P/J765 and P/J755 are connected correctly. Y↓N→Connect P/J765 and P/J755. Check the wire between J765 and J755 for an open circuit or a short circuit. The wire between J765 and J755 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the DADF PWB (PL 15.3) P754-1 (+) and GND (-), and between P754-7 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the DADF PWB (PL 15.3). Replace the DADF Registration Motor (PL 15.9). If the problem persists, replace the DADF PWB (PL 15.3). Replace the DADF PWB (PL 15.3).