Mã lỗi 010-320 — Xerox WorkCentre 5225

Code: 010-320

Description: Heat Roll Over Temperature Failure RAP • The Control (Center) Thermistor detected a temperature higher than the specified value. • The Rear Thermistor detected a temperature higher than the specified value.
Remedy: NOTE: When [010-320] occurs, NVM[744-220 FuserOverTemp]=1. After repair, change it to NVM[744-220 FuserOverTemp]=0. Check the resistance of the Control (Center) Thermistor between J600-5 and J600-6. The resistance is 3k Ohms or higher. Y↓N→Replace the Fuser Unit (PL 5.1). Check the resistance of the Rear Thermistor between J600-2 and J600-4. The resistance is 3k ohms or higher. Y↓N→Replace the Fuser Unit (PL 5.1). Check the wire between P/J410 and J600 for a short circuit. The wire between J410 and J600 is conducting without a short circuit. Y↓N→Repair the open circuit or short circuit. Check the wire between P/J401 and P/J523 for an open circuit or a short circuit. The wire between J401 and J523 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Replace the Fuser Unit (PL 5.1). If the problem persists, replace the Power Unit (PL 9.1). If the problem persists, replace the MCU PWB (PL 9.1).