Code: 012-283
Description: (A-Finisher) Set Clamp Home Sensor ON Fail In the initialize operations each at Power On, when Interlock closed and at the start of a job, and in the Set Clamp Motor’s ejecting operation, the Set Clamp Home Sensor was not detected turning On within a specified time after the start of the Set Clamp Motor operation.
Remedy: Check the Set Clamp mechanism for a deformed or broken part and not-seated belts. The mechanism is free from defects and belt damage. Y↓N→Repair the Set Clamp mechanism. Enter Component Control [012-251]. Rotate the Set Clamp Shaft by hand to block and unblock the Set Clamp Home Sensor. The display changes. Y↓N→Check the connections of P/J8707, P/J8742B, P/J8742A and P/J8723. P/J8707, P/ J8742B, P/J8742A and P/J8723 are securely connected. Y↓N→Connect P/J8707, P/J8742B, P/J8742A and P/J8723 securely. Check for an open or short circuit between J8707 and J8742B, and between J8742A and J8723. The wires between J8707 and J8742B and between J8742A and J8723 are OK. Y↓N→Repair the open or short circuit. Measure the voltage between Finisher PWB J8707-9 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Go to Wirenet A-Finisher +5VDC and check the +5VDC circuit. Measure the voltage between Finisher PWB J8707-8 (+) and GND (-). Rotate the Set Clamp Shaft by hand to block and unblock the Set Clamp Home Sensor. The voltage changes. Y↓N→Replace the Set Clamp Home Sensor (PL 22.4). Check the wires and connectors for an intermittent open or short circuit. If the problem continues, replace the Finisher PWB (PL 22.7). Enter [012-017]. The Set Clamp Motor rotates. Y↓N→Check the connections of P/J8706 and P/J8740. P/J8706 and P/J8740 are securely connected. Y↓N→Connect P/J8706 and P/J8740 securely. Check for an open or short circuit between J8706 and J8740. The wires between J8706 and J8740 are OK. Y↓N→Repair the open or short circuit. Measure the voltage between Finisher PWB J8706-9 (+) and GND (-), and between J8706-11 (+) and GND (-). Each voltage is approx. +24VDC. Y↓N→Go to Wirenet A-Finisher +24VDC and check the +24VDC circuit. If the problem continues, replace the Finisher PWB (PL 22.7). Replace the Set Clamp Motor (PL 22.9). If the problem continues, replace the Finisher PWB (PL 22.7). Check the wires and connectors for an intermittent open or short circuit. If the problem continues, replace the Finisher PWB (PL 22.7).