Description: Set Clamp Home Sensor On Failure RAP After the Set Clamp started operation, the Set Clamp Home Sensor did not turn On within 200ms.
Remedy: Manually operate the Eject mechanism. The Eject mechanism moves smoothly. Y↓N→Replace the parts that are interfering with operation. Execute Component Control[012-251 Set Clamp Home Sensor]. Actuate the Eject Clamp Home Sensor with paper. The display changes. Y↓N→Check the connections of J8871 and P/J8988. J8871 and P/J8988 are connected correctly. Y↓N→Connect J8871 and P/J8988. Check the wire between J8871 and J8988 for an open circuit or a short circuit. The wire between J8871 and J8988 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the Finisher PWB P8988-12 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the Finisher PWB (PL 23.16). Measure the voltage between the Finisher PWB P8988-11 (+) and GND (-). Actuate the Eject Clamp Home Sensor with paper. The voltage changes. Y↓N→Replace the Eject Clamp Home Sensor (PL 23.11). Replace the Finisher PWB (PL 23.16). Alternately execute Component Control[012-054 Eject Motor FWD LO] and Component Control[ 012-055 Eject Motor FWD HI]. The Eject Motor (PL 22.9) starts up. Y↓N→Check the connections of P/J8878 and P/J8983. P/J8878 and P/J8983 are connected correctly. Y↓N→Connect P/J8878 and P/J8983. Check the wire between J8878 and J8983 for an open circuit or a short circuit. The wire between J8878 and J8983 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the resistance of the Eject Motor (PL 22.9) between each point of J8878-1/3/4/6. The resistance is approx. 2Ohm. Y↓N→Replace the Eject Motor (PL 22.9). Measure the voltage between the Finisher PWB (PL 23.16) P8983-5/6/7/8 (+) and GND (- ). The voltage is approx. +24VDC. Y↓N→Replace the Finisher PWB (PL 23.16). Replace the Eject Motor (PL 22.9). If the problem persists, replace the Finisher PWB (PL 23.16). Replace the Finisher PWB (PL 23.16).