Mã lỗi 012-303 — Xerox WorkCentre 5225

Code: 012-303

Description: Finisher H-Transport Cover Open RAP The Finisher H-Transport Cover is open.
Remedy: Check opening/closing of the Finisher H-Transport Cover. The Finisher H-Transport Cover can be opened/closed. Y↓N→Reinstall the Finisher H-Transport Cover correctly. Check the installation of the H-Transport Interlock Sensor. The H-Transport Interlock Sensor is installed correctly. Y↓N→Install the H-Transport Interlock Sensor correctly. Execute Component Control[012-303 H-Transport Interlock Sensor]. Open and close the Finisher H-Transport Cover. The display changes. Y↓N→Check the connections of J8860 and J8987. J8860 and J8987 are connected correctly. Y↓N→Connect J8860 and J8987. Check the wire between J8860 and J8987 for an open circuit or a short circuit. The wire between J8860 and J8987 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the Finisher PWB P8987-1 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the H-Transport Interlock Sensor (PL 23.4). Measure the voltage between the Finisher PWB P8987-2 (+) and GND (-). Open and close the Finisher H-Transport Cover. The voltage changes. Y↓N→Replace the H-Transport Interlock Sensor (PL 23.4). Replace the Finisher PWB (PL 23.16). Replace the Finisher PWB (PL 23.16). If the problem persists, replace the MCU PWB (PL 9.1).

← Xem tất cả mã lỗi Xerox WorkCentre 5225

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie