Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 024-977 — Xerox WorkCentre 5225

Code: 024-977

Description: Stapler Feed Ready Failure RAP When starting Staple, Staple Ready Sensor Off was detected. Empty stapling was within 13 times.
Remedy: Execute Component Control[012-243 Staple Ready Sensor]. Install and remove the Staple Cartridge. The display changes. Y↓N→Check the Staple Cartridge for failure or foreign substances. There are no foreign substances and nothing has failed. Y↓N→Repair the failure and remove the foreign substances. Check the connections of J8886 and P/J8981. J8886 and P/J8981 are connected correctly. Y↓N→Connect J8886 and P/J8981. Check the wire between J8886 and J8981 for an open circuit or a short circuit. The wire between J8886 and J8981 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the Finisher PWB P8981-4 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the Finisher PWB (PL 23.16). Measure the voltage between the Finisher PWB P8981-6 (+) and GND (-). Install and remove the Staple Cartridge. The voltage changes. Y↓N→Replace the Finisher PWB (PL 23.16). Replace the Staple Assembly (PL 23.8). If the problem persists, replace the Finisher PWB (PL 23.16). Replace the Finisher PWB (PL 23.16). If the problem persists, replace the MCU PWB (PL 9.1).

← Xem tất cả mã lỗi Xerox WorkCentre 5225

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie