Code: 024-982
Description: (A-Finisher) Stacker Lower Safety Warning The condition below occurred four consecutive times. • In the operation of adjusting the height of the Stacker Tray (lowering the tray) for paper to be ejected during a job, the height of it cannot be adjusted within a specified time.
Remedy: Check for remaining paper and foreign objects on the Stacker Tray. The Stacker Tray is free from paper and/or foreign objects. Y↓N→Remove the remaining paper and/or foreign object(s). Check the drive mechanism to the Stacker Tray for a deformed or broken part and not-seated gears. The drive mechanism is free of defects and gears seat properly. Y↓N→Repair the Stacker Tray mechanism. Run DC330[012-267]. Enter Component Control [012-267]. Block and unblock the acceptance surface of the Stack Height Sensor with a piece of paper. The display changes. Y↓N→Check the connections of P/J8708 and P/J8727. P/J8708 and P/J8727 are securely connected. Y↓N→P/J8708 and P/J8727 are securely connected. Check for an open or short circuit between J8708 and J8727. The wires between J8708 and J8727 are OK. Y↓N→Repair the open or short circuit. Measure the voltage between J8708-3 (+) on the Finisher PWB and GND (-). The voltage is approx. +5VDC. Y↓N→Go to Wirenet A-Finisher +5VDC and check the +5VDC circuit. Measure the voltage between J8708-2 (+) on the Finisher PWB and GND (-). Block and unblock the Stack Height Sensor with a piece of paper. The voltage changes. Y↓N→Replace the Stack Height Sensor (PL 22.10). Check the wires and connectors for an intermittent open or short circuit. If the problem continues, replace the Finisher PWB (PL 22.7). Run DC330[012-278]. Enter [012-278]. Rotate the Stacker Stack Sensor 1 actuator by hand to block and unblock the sensor. The display changes. Y↓N→Check the connections of P/J8707 and P/J8722. P/J8707 and P/J8722 are securely connected. Y↓N→Connect P/J8707 and P/J8722 securely. Check for an open or short circuit between J8707 and J8722. The wires between J8707 and J8722 are OK. Y↓N→Repair the open or short circuit. Measure the voltage between J8707-6 (+) on the Finisher PWB and GND (-). The voltage is approx. +5VDC. Y↓N→Go to Wirenet A-Finisher +5VDC and check the +5VDC circuit. Measure the voltage between J8707-5 (+) on the Finisher PWB and GND (-). Rotate the Stacker Stack Sensor 1 actuator by hand to block and unblock the sensor. The voltage changes. Y↓N→Replace the Stacker Stack Sensor 1 (PL 22.8). Check the wires and connectors for an intermittent open or short circuit. If the problem continues, replace the Finisher PWB (PL 22.7). Run DC330[012-279]. Enter [012-279]. Rotate the Stacker Stack Sensor 2 actuator by hand to block and unblock the sensor. The display changes. Y↓N→Check the connections of P/J8707 and P/J8721. P/J8707 and P/J8721 are securely connected. Y↓N→Connect P/J8707 and P/J8721 securely. Check for an open or short circuit between J8707 and J8721. The wires between J8707 and J8721 are OK. Y↓N→Repair the open or short circuit. Measure the voltage between J8707-3 (+) on the Finisher PWB and GND (-). The voltage is approx. +5VDC. Y↓N→Go to Wirenet A-Finisher +5VDC and check the +5VDC circuit.