Mã lỗi 042-325 — Xerox WorkCentre 5225

Code: 042-325

Description: Main Motor Failure RAP The Main Motor is not rotating at the specified speed.
Remedy: Close the LH Cover and the Front Cover. Execute Component Control [042-001 Main Motor ON]. The Main Motor can be heard. Y↓N→Go to the OF 3 (MAIN DRIVE ASSY RAP). Check the installation of the Main Drive Assembly (PL 1.1). The Main Drive Assembly is installed correctly. Y↓N→Install the Main Drive Assembly correctly. Check the wire between J410 and J214 for an open circuit or a short circuit. The wires are conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Manually rotate the Main Motor rotor. It rotates smoothly. Y↓N→Check for foreign substances that are interfering with operation or installation failure. Foreign substances or installation failure are found. Y↓N→Replace the Main Drive Assembly (PL 1.1). Remove the foreign substances that are interfering with operation and correct the installation failure. Replace the Main Drive Assembly (PL 1.1) If the problem persists, replace the MCU PWB (PL 9.1).