Mã lỗi 062-300 — Xerox WorkCentre 5225

Code: 062-300

Description: Platen Interlock Open RAP The Platen Interlock is open
Remedy: Check opening/closing of the Platen Cover. The Platen Cover can be opened/closed. Y↓N→Reinstall the Platen Cover correctly. Check the installation of the Platen Angle Sensor. The Platen Angle Sensor is installed correctly. Y↓N→Install the Platen Angle Sensor correctly. Execute Component Control [062-301 Platen Angle Sensor]. Open and close the Platen Cover. The display changes. Y↓N→Check the connections of P/J725 and P/J722. P/J725 and P/J722 are connected correctly. Y↓N→Connect P/J725 and P/J722. Check the wire between J725 and J722 for an open circuit or a short circuit. The wire between J725 and J722 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the IIT/IPS PWB P722-B7 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the IIT/IPS PWB (PL 11.3). Measure the voltage between the IIT/IPS PWB P722-B9 (+) and GND (-). Actuate the Platen Angle Sensor with paper. The voltage changes. Y↓N→Replace the Platen Angle Sensor (PL 11.4). Replace the Platen Angle Sensor (PL 13.4). Replace the IIT/IPS PWB (PL 11.3).