Mã lỗi 062-360 — Xerox WorkCentre 5225

Code: 062-360

Description: Carriage Position RAP • An error occurred while counting the pulses of the Carriage Motor. • After the Carriage Motor turned On, the IIT Registration Sensor did not turn On within the specified time.
Remedy: Check the Carriage Rail for dirt or contamination or distortion. Dirt or contamination or distortion is found in the Carriage Rail. Y↓N→Clean the rails or correct the distortion (PL 11.4). Execute Component Control [062-212 IIT Registration Sensor]. Actuate the IIT Registration Sensor with paper. The display changes. Y↓N→Check the connections of P/J728 and P/J7193. P/J728 and P/J7193 are connected correctly. Y↓N→Connect P/J728 and P/J7193. Check the wire between J728 and J7193 for an open circuit or a short circuit. The wire between J728 and J7193 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the IIT/IPS PWB P7193-B10 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the IIT/IPS PWB (PL 11.3). Measure the voltage between the IIT/IPS PWB P7193-B12 (+) and GND (-). Actuate the IIT Registration Sensor (PL 11.4) with paper. The voltage changes. Y↓N→Replace the IIT Registration Sensor (PL 11.4). Replace the IIT/IPS PWB (PL 11.3). Alternately execute Component Control[062-005 Carriage Motor SCAN ON] and Component Control[062-006 Carriage Motor RETURN ON]. The Carriage Motor starts up. Y↓N→Check the connection P/J721. P/J721 is connected correctly. Y↓N→Connect P/J721. Check the wires on J721 for an open circuit or a short circuit. The wires on J721 are conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the resistance of the Carriage Motor (PL 11.5). The resistance between J721- 1/2 and J721-3/4/5/6 is approx. 1Ohm. Y↓N→Replace the Carriage Motor (PL 11.5). Measure the voltage between the IIT/IPS PWB (PL 11.3) P721-1/2 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the IIT/IPS PWB (PL 11.3). Replace the Carriage Motor (PL 11.5) If the problem persists, replace the IIT/IPS PWB (PL 11.3). Replace the IIT/IPS PWB (PL 11.3).

← Xem tất cả mã lỗi Xerox WorkCentre 5225

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie