Mã lỗi 077-104 — Xerox WorkCentre 5225

Code: 077-104

Description: Exit Sensor off (too short) JAM RAP After the Fuser Exit Sensor turned On, the Fuser Exit Sensor turned Off before the specified time
Remedy: Check the installation of the Fuser. The Fuser is installed correctly. Y↓N→Install the Fuser correctly. Check for foreign substances, distortion and paper powder in the paper transport path. No foreign substances, distortion or paper powder are found in the paper transport path. Y↓N→Clear away the foreign substances and paper powder. Correct the distortion. Execute Component Control [010-100 Fuser Exit Sensor]. Manually activate the actuator of the Fuser Exit Sensor (PL 5.1). The display changes. Y↓N→Check the connections of P/J125 and P/J410. P/J125 and P/J410 are connected correctly. Y↓N→Connect P/J125 and P/J410. Check the wire between J125 and J410 for an open circuit or a short circuit. The wire between J125 and J410 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the MCU PWB P410-1 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the MCU PWB (PL 9.1). Measure the voltage between the MCU PWB P410-3 (+) and GND (-). Actuate the Fuser Exit Sensor with paper. The voltage changes. Y↓N→Replace the Fuser Exit Sensor (PL 5.1). Replace the MCU PWB (PL 9.1). Execute Component Control [071-036 Main Motor ON]. The Main Motor in the Main Drive Assembly starts rotating and the Fuser starts up. Y↓N→Go to the OF 3 (MAIN DRIVE ASSY RAP). Replace the MCU PWB (PL 9.1).

← Xem tất cả mã lỗi Xerox WorkCentre 5225

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie