Description: Detected different Type Tray Module RAP A Tray Module with different specifications is connected.
Remedy: Check the settings for the DIP SW on the Tray Module PWB. The specifications are correct. Y↓N→Set the correct specifications. Check the connection of each MCU PWB connector. The connectors are connected correctly. Y↓N→Connect the connectors. Check the connection of each 2TM PWB or TTM PWB connector. The connectors are connected correctly. Y↓N→Connect the connectors. Turn on the power again. [077-211] reoccurs. Y↓N→End Check the wire between P/J541 and P/J413 for an open circuit or a short circuit. The wire between J541 and J413 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the MCU PWB P413-A5 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the MCU PWB (PL 9.1). Replace the 2TM PWB (PL 12.6/PL 13.8) or the TTM PWB (PL 12.6/PL 13.8). If the problem persists, replace the MCU PWB (PL 9.1).