Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 077-300 — Xerox WorkCentre 5225

Code: 077-300

Description: IOT Front Cover Open RAP The IOT Front Cover is open.
Remedy: Check the opening/closing of the IOT Front Cover. The Front Cover can be opened/closed. Y↓N→Reinstall the Front Cover. Check the installation of the Front Cover Interlock Switch. The Front Cover Interlock Switch is installed correctly. Y↓N→Install the Front Cover Interlock Switch correctly. Execute Component Control [071-303 Front Cover Interlock Switch]. Open/close the IOT Front Cover. The display changes. Y↓N→Check the connections of P/J121 and P/J405. P/J121 and P/J405 are connected correctly. Y↓N→Connect P/J121 and P/J405. Check the wire between J405 and J121 for an open circuit or a short circuit. The wire between J405 and J121 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Check the conductivity of the Front Cover Interlock Switch (PL 10.1) between J405-3 and J405-4. The wire between J405-3 and J405-4 is connecting successfully when the Front Cover is closed, and is insulated when the cover is open. Y↓N→Replace the Front Cover Interlock Switch (PL 10.1). Replace the MCU PWB (PL 9.1). Replace the MCU PWB (PL 9.1).

← Xem tất cả mã lỗi Xerox WorkCentre 5225

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin