Mã lỗi 077-305 — Xerox WorkCentre 5225

Code: 077-305

Description: Tray Module Left Hand Cover Interlock Open RAP • The 2TM Cover is open. • The TTM Cover is open.
Remedy: Check opening/closing of the Left Cover of the 2TM or TTM. The Left Cover of the 2TM or TTM can be opened/closed. Y↓N→Reinstall the Left Cover of the 2TM or TTM (PL 12.4/PL 13.7). Check the installation of the Tray Module Interlock Switch. The Tray Module interlock Switch is installed correctly. Y↓N→Install the Tray Module interlock Switch (PL 12.4/PL 13.7) correctly. Execute Component Control [071-301 Tray Module Left Cover Interlock Switch]. Open and close the Left Cover of the 2TM or TTM. The display changes. Y↓N→Check the connections of P/J554, FS812 and FS813. P/J554, FS812 and FS813 are connected correctly. Y↓N→Connect P/J554, FS812 and FS813. Check the wire between J554-2 and FS812, and between J554-1 and FS813 for an open circuit or a short circuit. The wires between J554-2 and FS812, and between J554-1 and FS813 are conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Check the conductivity of the Tray Module Left Cover Interlock Switch (PL 12.4/PL 13.7) between FS813 and FS812. The wire between FS813 and FS812 is connecting successfully when the 2TM Cover or TTM Cover is closed, and is insulated when the cover is open. Y↓N→Replace the Tray Module Left Cover Interlock Switch (PL 12.4/PL 13.7). Replace the Tray Module PWB (PL 12.6/PL 13.8). Replace the Tray Module PWB (PL 12.6/PL 13.8).

← Xem tất cả mã lỗi Xerox WorkCentre 5225

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie