Description: HCF to Registration Sensor Fault RAP The paper transported from HCF did not turn on the Registration Sensor within the specified time.
Remedy: Execute Component Control [089-100 Reg. Sensor]. Place paper in front of the Reg. Sensor. The display changes. Y↓N→Go to 8.7 BSD and check the following for an open wire, short or poor contact: • Reg Sensor P/J104-2 to MCU PWB P/J403-B8 • Reg Sensor P/J104-1 to MCU PWB P/J403-B13 • Reg Sensor P/J104-3 to MCU PWB P/J403-B3 If OK, replace the Reg. Sensor (PL 2.4) before replacing the MCU PWB (PL 9.1). Execute Component Control [078-007 Tray 6 Takeaway Motor]. There is operation noise from the Tray 6 Takeaway Motor. Y↓N→Check the wire-wound resistance of Pre Reg. Motor is approx. 0.8 ohms at the measurement points below. • JF57-3 to pins 1/2 • JF57-4 to pins 5/6 If OK, go to 8.9 BSD and troubleshoot the Tray 6 Takeaway Motor circuit. Check the following: • Takeaway Rolls 1 and 2 and 3 for dirt/paper particles/wear/a poor rotation • Pre Reg Roll for dirt/paper particles/wear/a poor rotation • Drive gears for wear/breakage • Drawer Connectors and contact points for foreign objects/bent pins/burnout • If the results of the above checks are OK, replace Tray Module PWB (PL 13.8) and the MCU PWB (PL 9.1) one at a time in the order shown