Code: 078-941
Description: HCF Paper Tray Size Mismatch RAP HCF Paper Size Mismatch.
Remedy: Check connectors JF01, PF/JF51, PF/JF52, and PF/JF53 are connected correctly. The connectors are connected correctly. Y↓N→Connect JF01, PF/JF51, PF/JF52, and PF/JF53. Enter Component Control [078-202, Tray 6 Size Sensor (Letter)]. Actuate the sensor with a piece of paper. The display changes. Y↓N→Go to 7.15 BSD and check the following for an open wire, short or poor contact: • Tray 6 Size Sensor (Letter) Sensor JF51-2 to HCF PWB JF01-11 • Tray 6 Size Sensor (Letter) Sensor PF51-3 to HCF PWB JF01-12 • Tray 6 Size Sensor (Letter) Sensor PF51-1 to HCF PWB JF01-10 If OK, replace the Tray 6 Size Sensor (PL 18.8) then the HCF PWB (PL 18.8). Component Control [078-203, Tray 6 Size Sensor (A3)]. Actuate the sensor with a piece of paper. The display changes. Y↓N→Go to 7.15 BSD and check the following for an open wire, short or poor contact: • Tray 6 Size Sensor (A3) Sensor JF52-2 to HCF PWB JF01-8 • Tray 6 Size Sensor (A3) Sensor JF52-3 to HCF PWB JF01-9 • Tray 6 Size Sensor (A3) Sensor JF52-1 to HCF PWB JF01-7 If OK, replace the Tray 6 Size Sensor (PL 18.8) then the HCF PWB (PL 18.8). Component Control [078-204, Tray 6 In Sensor]. Actuate the sensor with a piece of paper. The display changes. Y↓N→Go to 7.15 BSD and check the following for an open wire, short or poor contact: • Tray 6 Size Sensor (A3) Sensor JF53-2 to HCF PWB JF01-5 • Tray 6 Size Sensor (A3) Sensor JF53-3 to HCF PWB JF01-6 • Tray 6 Size Sensor (A3) Sensor JF53-1 to HCF PWB JF01-4 If OK, replace the Tray 6 In Sensor (PL 18.1) then the HCF PWB (PL 18.8). Ensure the paper guilds are adjusted correctly to the paper size.