Description: Waste Toner Bottle Position RAP The Waste Toner Bottle is not in the correct position.
Remedy: Check the installation of the Waste Toner Bottle. Waste Toner Bottle installation is correct. Y↓N→Correct the installation problem by checking for damaged mounting points. Verify the condition of the circuit, BSD9.9, between the Waste Toner Position Sensor and MCU PWB. The circuit is free of damage. Y↓N→Repair the circuit as required. Ensure the Waste Toner Bottle is installed correctly. Then check Waste Toner Bottle sensor operating voltage and output. The signal level voltage indicates the Waste Toner Bottle is correctly installed. Y↓N→There is a problem with the sensor. Repair or replace the Waste Toner Position Sensor (PL 4.2). Replace the MCU PWB (PL 9.1).