Code: 007-340
Description: Main Motor Failure Fuser Error
Causes: • Main Drive Assembly, PL6.1.2 • Harness Assembly Main MOT, PL 6.1.7 • MCU Board, PL7.2.2
Remedy: 1 Check these connections • MCU Board P/J16 • Main Drive Assembly P/J160 Are the connectors secure? Go to step 3. Secure the connectors and then go to step 2. 2 Does the error persist? Go to step 3. Complete. 3 Check the Main Drive Assembly for rotation. For the 6000B, see gDigital Output Test Proceduresh on page A-16, or for the 6015 MFPs, see gWorkCentre 6015 MFP Motor Test Proceduresh. Does the Main Drive Assembly function normally? Replace the MCU Board. Go to step 4. 4 Check the Main Drive Assembly for proper installation. Is the Main Drive Assembly installed correctly? Go to step 6. Reseat the Main Drive Assembly, and go to step 5. 5 Does the error persist? Go to step 6. Complete. 6 Checking the Harness Assembly Main MOT for continuity. Disconnect P/J16 from the MCU Board, and P/J160 from the Main Drive Assembly. Is each cable of P/J16 <=> P/J160 continuous? Go to step 7. Repair the harness. 7 Disconnect the P/J16 on the MCU Board. Are the voltages across ground to P/J6-2pin/P/J6-4 pin on the MCU Board approximately +24 VDC when the Interlock Switch is pushed? Replace the Main Drive Assembly. Replace the MCU Board.