Remedy: 1 Check the connections between the FAN and LVPS. Is P/J205 on the LVPS securely connected? Go to step 2. Reconnect connector P/J205, then go to step 2. 2 Does the error persist? Go to step 3. Complete. 3 Disconnect P/J205 on the LVPS. Is the voltage across ground at P/J205-1 approximately +24 VDC when the Interlock Switch is pushed? Go to step 4. Replace the LVPS. 4 For the 6010N: Test the Fan (see “Using Phaser 6010N and WorkCentre 6015 MFP Service Diagnostics”). For the 6000: Test the Fan with the CE Diags Tool (see page A-16). Does the Fan function normally? Complete. Replace the MCU Board.