Code: U2
Display: U2:ROS FAIL
Description: There is a problem with the ROS Assy.
1. BD signal intervals are longer than specified value after ROS Motor start rotating.
2. After the interval of transmitting /BD signal reaches the specified value, the interval is longer than the specified value.
3. When the laser power does not reach the specified value.
1. BD signal intervals are longer than specified value after ROS Motor start rotating.
2. After the interval of transmitting /BD signal reaches the specified value, the interval is longer than the specified value.
3. When the laser power does not reach the specified value.
Remedy: 1 INITIAL ANALYSIS Inspect the following components. • ROS Assy • PWBA HKB26 MCU • PWBA HKB PS • CRU • Harness Assy ROS (J21-J211, J212, J213) • Harness Assy VDO (J22-J233) Are they compatible with your printer version, correctly installed, not damaged, deformed, or contaminated? Go to step 2. Replace the problem components. 2 NVRAM ANALYSIS Check the parameter using ADJUSTMENT MODE MENU. Is the parameters set correctly? Go to step 3. Set correct paramete.r 3 ROS MOTOR ANALYSIS 1. Check the ROS Motor using ROS MOTOR TEST. 2. If you cannot hear the ROS Motor running, unplug P/J29 (Motor Assy Main). Can you hear the ROS Motor running before the U2 code appears? Go to step 4. Go to 6.3 ROS Assy Failure. 4 LD DIODE ANALYSIS 1. Disconnect P/J22 and P/J21 on the PWBA HKB26 MCU . 2. Close the Cover Assy Front . 3. Switch ON Main Power. 4. Check the voltage between P21-5 and P21-6. Is there +5 VDC between P21-5 and P21-6? Go to 6.3 ROS Assy Failure. Go to 6.1 PWBA HKB PS Failure (+3.3 VDC).