Code: U4

Display: U4:FUSER FAIL
Description: There is a problem with the Fuser Assy.
1. Fuser Assy temperature is does not reach the temperature even after 110 seconds passed.
2. Fuser Assy temperature gets lower than [SetTemp. 125 C], in printing.
3. Fuser Assy temperature gets higher than [SetTemp. 220 C].
4. The thermistor disconnection is detected.
5. The heat lamp continuously turns on for 10 seconds during the Standby Mode.
Remedy: 1 INITIAL ANALYSIS Inspect the following components. • Fuser Assy • Harness Assy Fuser-M (J271, J11, J27, J262) • PWBA HKB26 MCU • PWBA HKB PS • Switch Assy I/L Front • Switch Assy I/L Rear • Sensor Photo Exit in the Fuser Assy Are they compatible with your printer version, correctly installed, not damaged, deformed, or contaminated? Go to step 2. Replace the problem components. 2 SWITCH ASSY I/L FRONT ANALYSIS Check the Switch Assy I/L Front function using SENSOR/ SWITCH CHECH. Does the Switch Assy I/L Front function correctly and increment the Sensor Check number each time you actuate it? Go to step 3. Replace the Switch Assy I/ L Front 3 SWITCH ASSY I/L REAR ANALYSIS Check the Switch Assy I/L Rear function using SENSOR/ SWITCH CHECH. Does the Switch Assy I/L Rear function correctly and increment the Sensor Check number each time you actuate it? Go to step 4. Replace the Switch Assy I/ L Rear . 4 HARNESS ASSY FUSER-M (J271, J11, J27, J262) ANALYSIS Is there continuity between J271 and J11? Go to step 5. Replace the Harness Assy Fuser-M (J271, J11, J27, J262) . 5 HEATER ASSY ANALYSIS Does U4 appear after POWER–ON? (Answer YES if there is a momentary Fuser Assy Warm-Up Sequence) Go to 6.5 Temperature Sensor Failure. Go to step 6. 6 HEAT ROD ANALYSIS Let the Heat Rod cool down. Does the Heat Rod glow when power is switched ON? Go to step 6. Go to 6.4 Heat Rod Failure. 7 Does the Heat Rod switch ON and OFF after Power–On Sequence? Go to step 8. Go to step 9. 8 HEAT ROD ANALYSIS Is there proper VAC between P/J11-1 and P/J11-2? Go to 6.5 Temperature Sensor Failure. Replace the PWBA HKB PS . 9 PWBA HKB PS ANALYSIS Perform this check within 65 seconds after switching power ON. After specified seconds, PWBA HKB PS shuts down due to a no–load condition. Is there +3.3VDC between P/J281-10 and P/J28-8 on the PWBA HKB PS? Go to step 10. Go to 6.1 LVPS Failure (+3.3VDC). 10 HEAT ROD ACTUATOR SIGNAL ANALYSIS Disconnect P/J28 on the PWBA HKB26 MCU . Is there 0VDC between P/J 28-12 and P/J 28-8 on the PWBA HKB26 MCU during Power–ON sequence, and does the voltage rise to +3.3VDC when the sequence finishes? Go to 6.1 PWBA HKB PS Failure (+3.3 VDC). Replace the PWBA HKB26 MCU .

← Xem tất cả mã lỗi OKI B6100

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie