Code: 004C
Description: Ozone ventilation fan motor malfunction
• The ozone ventilation fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the ozone ventilation fan motor is being rotated.
• The ozone ventilation fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the ozone ventilation fan motor is being rotated.
Causes: Ozone ventilation fan motor (FM2) Printer control board (PRCB)
Remedy: 1 Check the FM2 connector for proper connection and correct as necessary. - - 2 Check the fan for possible overload and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 FM2 operation check. PRCB PJ16-1 (REM) PRCB PJ16-3 (LOCK) C110: C-4 C130n: C-4 5 Change FM2. - - 6 Change PRCB. - -