Description: Transport motor malfunction • The motor lock signal remains HIGH for a predetermined consecutive period of time while the transport motor remains energized. • The rack positioning sensor is in the blocked state when the rack motor remains deenergized. • The rack positioning sensor is not blocked a second time even after the lapse of a predetermined period of time after it has been blocked once while the rack motor remains energized.
Causes: Transport motor (M1) Printer control board (PRCB) DC power supply (DCPU)
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. - - 2 Check M1 for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 M1 operation check. PRCB PJ8-1 to 6 C110: C-2 C130n: C-2 5 Change PRCB. - - 6 Change DCPU. - -
Description: Rack rotation failure • The rack positioning sensor is unable to detect the deceleration control position after the lapse of a given period of time after the rack motor has started while the rack motor is turning. • The count value of the edge of ON signal of the rack positioning sensor during each developing positions are not a predetermined value while the rack motor is turning.
Causes: Rack motor (M2) Rack positioning sensor (PS5) Printer control board (PRCB)
Remedy: 1 Check the M2 connector for proper connection and correct as necessary. - - 2 Check M2 for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 PS5 sensor check. PRCB PJ5-11 (ON) C110: C-11 to 12 C130n: C-11 to 12 5 M2 operation check. PRCB PJ5-5 to 8 C110: C-12 C130n: C-12 6 Change PRCB. - -
Description: Ozone ventilation fan motor malfunction • The ozone ventilation fan motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the ozone ventilation fan motor is being rotated.
Causes: Ozone ventilation fan motor (FM2) Printer control board (PRCB)
Remedy: 1 Check the FM2 connector for proper connection and correct as necessary. - - 2 Check the fan for possible overload and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 FM2 operation check. PRCB PJ16-1 (REM) PRCB PJ16-3 (LOCK) C110: C-4 C130n: C-4 5 Change FM2. - - 6 Change PRCB. - -
Description: Power supply cooling fan motor malfunction • The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the power supply cooling fan motor remains energized.
Causes: DC power supply fan motor (FM1) Printer control board (PRCB) DC power supply (DCPU)
Remedy: 1 Check the FM1 connector for proper connection and correct as necessary. - - 2 Check the fan for possible overload and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 FM1 operation check. HV CN2-1 (REM) HV CN2-3 (LOCK) C110: B-5 C130n: B-4 to 5 5 Change PRCB. - - 6 Change DCPU. - -
Description: Transfer belt rotation failure • The belt positioning sensor does not detect the transfer belt position detection hole a second time even after the lapse of a predetermined period of time after it has detected one while the transfer belt is rotated.
Causes: Belt positioning sensor (PS6) Imaging cartridge Printer control board (PRCB)
Remedy: 1 Check the PRCB connector for proper connection and correct as necessary. - - 2 PS6 sensor check. - - 3 Change Imaging cartridge. - - 4 Change PRCB.
Description: 2nd image transfer pressure /retraction failure • The state of the 2nd image transfer retraction position sensor is not changed from the unblocked to blocked state even after the lapse of a predetermined period of time during predrive. • The 2nd image transfer retraction position sensor is in the unblocked state even after the lapse of a predetermined period of time during predrive. • The 2nd image transfer retraction position sensor is not blocked (roller in the retracted position) within a predetermined period of time after the retraction sequence of the 2nd transfer roller has been started. • The 2nd image transfer retraction position sensor is not unblocked (roller in the pressed position) within a predetermined period of time after the pressure sequence of the 2nd transfer roller has been started.
Causes: 2nd image transfer retraction position sensor (PS3) 2nd image transfer pressure/retraction solenoid (SD4) Transport motor (M1) Printer control board (PRCB)
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. - - 2 Check M1 for proper drive coupling and correct as necessary. - - 3 Check the SD4 connector for proper connection and correct as necessary. - - 4 Check the PRCB connector for proper connection and correct as necessary. - - 5 PS3 sensor check. PRCB PJ12-3 (ON) C110: C-2 to 3 C130n: C-2 6 SD4 operation check. PRCB PJ10-6 (REM) C110: C-9 C130n: C-9 7 M1 operation check. PRCB PJ8-1 to 6 C-2 8 Change PRCB. - -
Description: Polygon motor malfunction • A LOW motor lock signal is not detected even after the lapse of a predetermined period of time after the polygon motor has been started. • The motor lock signal remains HIGH for a predetermined consecutive period of time while the polygon motor remains energized.
Causes: PH unit Printer control board (PRCB)
Remedy: 1 Check the cable and connector for proper connection and correct as necessary. - - 2 Change PH unit. - - 3 Change PRCB. - -
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.