Code: 004E
Description: Power supply cooling fan motor malfunction
• The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the power supply cooling fan motor remains energized.
• The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the power supply cooling fan motor remains energized.
Causes: DC power supply fan motor (FM1) Printer control board (PRCB) DC power supply (DCPU)
Remedy: 1 Check the FM1 connector for proper connection and correct as necessary. - - 2 Check the fan for possible overload and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 FM1 operation check. HV CN2-1 (REM) HV CN2-3 (LOCK) C110: B-5 C130n: B-4 to 5 5 Change PRCB. - - 6 Change DCPU. - -