Code: 0001
Description: Transport motor malfunction
• The motor lock signal remains HIGH for a predetermined consecutive period of time while the transport motor remains energized.
• The rack positioning sensor is in the blocked state when the rack motor remains deenergized.
• The rack positioning sensor is not blocked a second time even after the lapse of a predetermined period of time after it has been blocked once while the rack motor remains energized.
• The motor lock signal remains HIGH for a predetermined consecutive period of time while the transport motor remains energized.
• The rack positioning sensor is in the blocked state when the rack motor remains deenergized.
• The rack positioning sensor is not blocked a second time even after the lapse of a predetermined period of time after it has been blocked once while the rack motor remains energized.
Causes: Transport motor (M1) Printer control board (PRCB) DC power supply (DCPU)
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. - - 2 Check M1 for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 M1 operation check. PRCB PJ8-1 to 6 C110: C-2 C130n: C-2 5 Change PRCB. - - 6 Change DCPU. - -