Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi OKI C130

Code: 0001

Description: Transport motor malfunction
• The motor lock signal remains HIGH for a predetermined consecutive period of time while the transport motor remains energized.
• The rack positioning sensor is in the blocked state when the rack motor remains deenergized.
• The rack positioning sensor is not blocked a second time even after the lapse of a predetermined period of time after it has been blocked once while the rack motor remains energized.
Causes: Transport motor (M1) Printer control board (PRCB) DC power supply (DCPU)
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. - - 2 Check M1 for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 M1 operation check. PRCB PJ8-1 to 6 C110: C-2 C130n: C-2 5 Change PRCB. - - 6 Change DCPU. - -

Code: 001B

Description: Rack rotation failure
• The rack positioning sensor is unable to detect the deceleration control position after the lapse of a given period of time after the rack motor has started while the rack motor is turning.
• The count value of the edge of ON signal of the rack positioning sensor during each developing positions are not a predetermined value while the rack motor is turning.
Causes: Rack motor (M2) Rack positioning sensor (PS5) Printer control board (PRCB)
Remedy: 1 Check the M2 connector for proper connection and correct as necessary. - - 2 Check M2 for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 PS5 sensor check. PRCB PJ5-11 (ON) C110: C-11 to 12 C130n: C-11 to 12 5 M2 operation check. PRCB PJ5-5 to 8 C110: C-12 C130n: C-12 6 Change PRCB. - -

Code: 004A

Description: Duplex unit cooling fan motor malfunction
Causes:
Remedy:

Code: 004C

Description: Ozone ventilation fan motor malfunction
• The ozone ventilation fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the ozone ventilation fan motor is being rotated.
Causes: Ozone ventilation fan motor (FM2) Printer control board (PRCB)
Remedy: 1 Check the FM2 connector for proper connection and correct as necessary. - - 2 Check the fan for possible overload and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 FM2 operation check. PRCB PJ16-1 (REM) PRCB PJ16-3 (LOCK) C110: C-4 C130n: C-4 5 Change FM2. - - 6 Change PRCB. - -

Code: 004E

Description: Power supply cooling fan motor malfunction
• The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the power supply cooling fan motor remains energized.
Causes: DC power supply fan motor (FM1) Printer control board (PRCB) DC power supply (DCPU)
Remedy: 1 Check the FM1 connector for proper connection and correct as necessary. - - 2 Check the fan for possible overload and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 FM1 operation check. HV CN2-1 (REM) HV CN2-3 (LOCK) C110: B-5 C130n: B-4 to 5 5 Change PRCB. - - 6 Change DCPU. - -

Code: 0092

Description: Transfer belt rotation failure
• The belt positioning sensor does not detect the transfer belt position detection hole a second time even after the lapse of a predetermined period of time after it has detected one while the transfer belt is rotated.
Causes: Belt positioning sensor (PS6) Imaging cartridge Printer control board (PRCB)
Remedy: 1 Check the PRCB connector for proper connection and correct as necessary. - - 2 PS6 sensor check. - - 3 Change Imaging cartridge. - - 4 Change PRCB.

Code: 0094

Description: 2nd image transfer pressure /retraction failure
• The state of the 2nd image transfer retraction position sensor is not changed from the unblocked to blocked state even after the lapse of a predetermined period of time during predrive.
• The 2nd image transfer retraction position sensor is in the unblocked state even after the lapse of a predetermined period of time during predrive.
• The 2nd image transfer retraction position sensor is not blocked (roller in the retracted position) within a predetermined period of time after the retraction sequence of the 2nd transfer roller has been started.
• The 2nd image transfer retraction position sensor is not unblocked (roller in the pressed position) within a predetermined period of time after the pressure sequence of the 2nd transfer roller has been started.
Causes: 2nd image transfer retraction position sensor (PS3) 2nd image transfer pressure/retraction solenoid (SD4) Transport motor (M1) Printer control board (PRCB)
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. - - 2 Check M1 for proper drive coupling and correct as necessary. - - 3 Check the SD4 connector for proper connection and correct as necessary. - - 4 Check the PRCB connector for proper connection and correct as necessary. - - 5 PS3 sensor check. PRCB PJ12-3 (ON) C110: C-2 to 3 C130n: C-2 6 SD4 operation check. PRCB PJ10-6 (REM) C110: C-9 C130n: C-9 7 M1 operation check. PRCB PJ8-1 to 6 C-2 8 Change PRCB. - -

Code: 0300

Description: Polygon motor malfunction
• A LOW motor lock signal is not detected even after the lapse of a predetermined period of time after the polygon motor has been started.
• The motor lock signal remains HIGH for a predetermined consecutive period of time while the polygon motor remains energized.
Causes: PH unit Printer control board (PRCB)
Remedy: 1 Check the cable and connector for proper connection and correct as necessary. - - 2 Change PH unit. - - 3 Change PRCB. - -