Code: 001B
Description: Rack rotation failure
• The rack positioning sensor is unable to detect the deceleration control position after the lapse of a given period of time after the rack motor has started while the rack motor is turning.
• The count value of the edge of ON signal of the rack positioning sensor during each developing positions are not a predetermined value while the rack motor is turning.
• The rack positioning sensor is unable to detect the deceleration control position after the lapse of a given period of time after the rack motor has started while the rack motor is turning.
• The count value of the edge of ON signal of the rack positioning sensor during each developing positions are not a predetermined value while the rack motor is turning.
Causes: Rack motor (M2) Rack positioning sensor (PS5) Printer control board (PRCB)
Remedy: 1 Check the M2 connector for proper connection and correct as necessary. - - 2 Check M2 for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 PS5 sensor check. PRCB PJ5-11 (ON) C110: C-11 to 12 C130n: C-11 to 12 5 M2 operation check. PRCB PJ5-5 to 8 C110: C-12 C130n: C-12 6 Change PRCB. - -