Code: 144-001
Description: SBU connection error
The SBU connection cannot be detected at power on or recovery from the energy save mode.
The SBU connection cannot be detected at power on or recovery from the energy save mode.
Causes: • Insufficient power supply for SBU • Defective SBU • Defective harness • Defective detection port on the BCU
Remedy: 1. Replace the harness. 2. Replace the SBU. 3. Replace the BICU.