Mã lỗi SC672 — Ricoh D124 MPCW2200SP

Code: SC672

Description: Controller start up error CTL •X After the machine was powered on, communication between the controller and the operation panel was not established, or communication with controller was interrupted after a normal startup. •X After startup reset of the operation panel, the attention code (FDH) or the attention acknowledge code (FEH) was not sent from the controller within 30 sec.. •X After the controller issued a command to check the communication line with the controller at 30-second intervals, the controller failed to respond twice.
Causes: •X Controller stalled •X Controller board installed incorrectly •X Controller board defective •X Operation panel connector loose, broken, or defective •X The controller did not completely shut down when the switch was turned off.
Remedy: •X Check the setting of SP5-875-001. •X If this SP is set to "1 (OFF)", change it to "0 (ON)"