Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh D124 MPCW2200SP

Code: SC101

Description: Scanner Lamp Error At power on the scan lamp trigger remained off.
Causes: •X CIS-to-IPU harness loose, broken, defective •X CIS-to-IOB harness loose, broken, defective •X IPU defective •X IOB defective •X CIS defective
Remedy:

Code: SC143

Description: Scanner Automatic Adjustment Error Automatic adjustment of the CIS failed at power on.
Causes: •X Standard white strips dirty or not platen white plate installed improperly •X CIS LED defective and not lighting •X CIS-to-PSU harness loose, broken, defective •X CIS-to-IPU harness loose, broken, defective •X CIS defective •X MCU defective •X SIF defective •X IPU defective
Remedy:

Code: SC144

Description: SIB Communication Error SIB serial transmission did not begin after power on.
Causes: •X SIF-to-IPU harness connector loose, broken, defective •X SIF defective •X MCU defective •X IPU defective
Remedy:

Code: SC161-02

Description: IPU Error 2: Ri2005 SIB Response Error. At power on, or when the machine returned from energy save mode, an IPU error occurred because Ri did not respond within 5 ms.
Causes: •X IPU defective
Remedy:

Code: SC161-03

Description: IPU Error 3: Ri2005 S-to-M Response Error At power on, or when the machine returned from energy save mode, the Ri2005 chip on the IPU did not respond within 5 ms.
Causes: •X IPU defective
Remedy:

Code: SC161-05

Description: IPU Error: Ri2005 M-to-P Response Error. At power on, or when the machine returned from energy save mode, the Ri2005 chip on the IPU did not respond within 5 ms.
Causes: •X IPU defective
Remedy:

Code: SC161-1

Description: IPU Error 1: Volans Configuration Error At power on, or when the machine returned from energy save mode, FPGA (flash program) did not configure correctly within 500 ms, or an FPGA communication check failed.
Causes: •X Check all harness connections to the IPU for a loose, broken, defective connection •X IPU defective
Remedy:

Code: SC165

Description: Illegal Copy Prevention Function Error The illegal copy prevention function failed to initialize at power on, or when the machine returned from the energy save mode, because the ICIB3 board was not detected or was not installed correctly. Note: The ICIB3 (option) is the PCB installed on the back of the machine that controls the function that prohibits illegal copying of currency, bank notes, etc.
Causes: •X Check installation and connection of the ICIB3 board •X ICIB3 defective
Remedy: