Mã lỗi 670-00 — Ricoh D193 MPC401SRSP Z-C2

Code: 670-00

Description: Engine start up error CTL The ready signal from the engine board was not detected.
Causes: Case 1 • No /ENGRDY signal asserted at power on, or when machine left low power mode. • No response from EC from engine within the specified time at power on. • No response from PC from engine within the specified time at power on. • No response from SC from engine within the specified time at power on (MFP module only). • Write to Rapi driver failed (no destination found at PCI). Case 2 • Unexpected error occurred after /ENGRDY signal asserted.
Remedy: • Check the connections between the controller and BCU • Replace the BCU for 100% failure • If occurrence of the error is sporadic, the firmware may need to be updated, or the controller board or PSU requires replacement