Mã lỗi 821 — Ricoh G189 SPC821DN AP-P2

Code: 821

Description: Self-diagnostics error: ASIC [XXXX]: Detailed error code
Causes: [0B00] ASIC error The write-&-verify check error has occurred in the ASIC. • Defective ASIC device Replace the controller. [0B06] ASIC detection error The I/O ASIC for system control is not detected. • Defective ASIC • Defective North Bridge and PCI I/F Replace the controller board. [0B10] SHM register error • The initialization of bus connection or read for SHM fails. • The register of SHM is different from specified value. • Defective connection bus • Defective SHM Replace the controller board [0D05] Self-diagnosis error: ASIC The CPU checks if the ASIC timer works correctly compared with the CPU timer. If the ASIC timer does not function in the specified range, this SC code is displayed. • System firmware problem • Defective RAM-DIMM • Defective controller 1. Reinstall the controller system firmware. 1. Replace the RAM-DIMM. 2. Replace the controller board.
Remedy: