Các lỗi thường gặp

Code :
  • Code: 195
  • Description: Serial Number Mismatch
    • Serial number stored in the memory does not have the correct code.
  • Causes: • NVRAM defective • EGB replaced without original NVRAM
  • Remedy: 1. Reinstall the original NVRAM in the replaced BCU. 2. Turn off and on the main power switch of the copier if a new NVRAM is installed in the BCU.
  • Code: 202
  • Description: Polygon motor error 1: ON timeout
    The polygon mirror motor does not reach the targeted operating speed within the specified time after turning on or changing speed
  • Causes: • Defective or disconnected harness to polygon motor driver board • Defective polygon motor driver board • Defective polygon motor.
  • Remedy: 1. Replace the polygon motor. 2. Replace the laser optics housing unit. 3. Replace the harness. 4. Replace the BCU.
  • Code: 203
  • Description: Polygon motor error 2: OFF timeout
    The polygon mirror motor does leave the READY status within 3 seconds after the polygon motor switches off.
  • Causes: • Disconnected or defective harness to polygon motor driver board • Defective polygon motor driver board • Defective polygon motor.
  • Remedy: 1. Replace the polygon motor. 2. Replace the laser optics housing unit. 3. Replace the harness. 4. Replace the BCU.
  • Code: 204
  • Description: Polygon motor error 3: XSCRDY signal error
    The SCRDY_N signal goes HIGH (inactive) while the laser diode is firing.
  • Causes: • Disconnected or defective harness to polygon motor driver board • Defective polygon motor • Defective polygon motor driver board.
  • Remedy: 1. Replace the polygon motor. 2. Replace the laser optics housing unit. 3. Replace the harness. 4. Replace the BCU.
  • Code: 210
  • Description: Laser synchronizing detection error: end position [K]
    The laser synchronizing detection signal for the end position of LDB [K], [Y], [M], [C] is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
  • Causes: • Disconnected or defective harness to synchronizing detector for end position • Defective synchronizing detector board • Defective LD board or driver • Defective EGB
  • Remedy: 1. Replace the harness of the LD board. 2. Replace the laser optics housing unit. 3. Replace the BCU.
  • Code: 211
  • Description: Laser synchronizing detection error: end position [Y]
    The laser synchronizing detection signal for the end position of LDB [K], [Y], [M], [C] is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
  • Causes: • Disconnected or defective harness to synchronizing detector for end position • Defective synchronizing detector board • Defective LD board or driver • Defective EGB
  • Remedy: 1. Replace the harness of the LD board. 2. Replace the laser optics housing unit. 3. Replace the BCU.
  • Code: 212
  • Description: Laser synchronizing detection error: end position [M]
    The laser synchronizing detection signal for the end position of LDB [K], [Y], [M], [C] is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
  • Causes: • Disconnected or defective harness to synchronizing detector for end position • Defective synchronizing detector board • Defective LD board or driver • Defective EGB
  • Remedy: 1. Replace the harness of the LD board. 2. Replace the laser optics housing unit. 3. Replace the BCU.
  • Code: 213
  • Description: Laser synchronizing detection error: end position [C]
    The laser synchronizing detection signal for the end position of LDB [K], [Y], [M], [C] is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
  • Causes: • Disconnected or defective harness to synchronizing detector for end position • Defective synchronizing detector board • Defective LD board or driver • Defective EGB
  • Remedy: 1. Replace the harness of the LD board. 2. Replace the laser optics housing unit. 3. Replace the BCU.