Description: Fixing Assembly high temperature error
The Fixing Sub Thermistor (THM2) detected 295 degrees C or higher for 200msec or longer on end.
Remedy: 1. Perform the following to clear the error: COPIER > FUNCTION > CLEAR > ERR in the Service Mode; then, turn the power switch to OFF and then ON.
2. Check the connection of the Fixing Assembly. (Connection error of the Drawer, connector disconnection, open circuit)
3. Check the connection between the AC Driver PCB (PCB4) and Fixing Assembly.
4. Replace the Fixing Assembly.
5. Replace the AC Driver PCB (PCB4).
6. Replace the DC Controller PCB (PCB1).