  • Code: E000-0001
  • Description: Fixing Assembly low temperature error
    The detected temperature of the Fixing Main Thermistor (THM1) failed to reach the specified temperature at the fixing start control.
  • Remedy: 1. Perform the following to clear the error: COPIER > FUNCTION > CLEAR > ERR in the Service Mode; then, turn the power switch to OFF and then ON.
    2. Check the connection of the Fixing Assembly. (Connection error of the Drawer, connector disconnection, open circuit)
    3. Check the connection between the AC Driver PCB (PCB4) and Fixing Assembly.
    4. Replace the Fixing Assembly.
    5. Replace the AC Driver PCB (PCB4).
    6. Replace the DC Controller PCB (PCB1).
  • Code: E001-0000
  • Description: Fixing Assembly high temperature error
    The Fixing Main Thermistor (THM1) detected 250 degrees C or higher for 200msec or longer on end.
  • Remedy: 1. Perform the following to clear the error: COPIER > FUNCTION > CLEAR > ERR in the Service Mode; then, turn the power switch to OFF and then ON.
    2. Check the connection of the Fixing Assembly. (Connection error of the Drawer, connector disconnection, open circuit)
    3. Check the connection between the AC Driver PCB (PCB4) and Fixing Assembly.
    4. Replace the Fixing Assembly.
    5. Replace the AC Driver PCB (PCB4).
    6. Replace the DC Controller PCB (PCB1).
  • Code: E001-0001
  • Description: Fixing Assembly high temperature error (hardware detection)
    The hardware circuit detected overheating of the Fixing Main Thermistor (THM1) or Fixing Sub Thermistor (THM2) for 30msec or longer on end.
  • Remedy: 1. Perform the following to clear the error: COPIER > FUNCTION > CLEAR > ERR in the Service Mode; then, turn the power switch to OFF and then ON.
    2. Check the connection of the Fixing Assembly. (Connection error of the Drawer, connector disconnection, open circuit)
    3. Check the connection between the AC Driver PCB (PCB4) and Fixing Assembly.
    4. Replace the Fixing Assembly.
    5. Replace the AC Driver PCB (PCB4).
    6. Replace the DC Controller PCB (PCB1).
  • Code: E001-0002
  • Description: Fixing Assembly high temperature error
    The Fixing Sub Thermistor (THM2) detected 295 degrees C or higher for 200msec or longer on end.
  • Remedy: 1. Perform the following to clear the error: COPIER > FUNCTION > CLEAR > ERR in the Service Mode; then, turn the power switch to OFF and then ON.
    2. Check the connection of the Fixing Assembly. (Connection error of the Drawer, connector disconnection, open circuit)
    3. Check the connection between the AC Driver PCB (PCB4) and Fixing Assembly.
    4. Replace the Fixing Assembly.
    5. Replace the AC Driver PCB (PCB4).
    6. Replace the DC Controller PCB (PCB1).
  • Code: E002-0000
  • Description: Fixing Assembly temperature rise error
    1. The Fixing Main Thermistor (THM1) detected the temperature of lower than 115 degrees C for 400msec or longer on end 6.0 seconds later after detecting 100 degrees C.
    2. The Fixing Main Thermistor (THM1) detected the temperature of lower than 150 degrees C for 400msec or longer on end 6.0 seconds later after detecting 140 degrees C.
  • Remedy: 1. Perform the following to clear the error: COPIER > FUNCTION > CLEAR > ERR in the Service Mode; then, turn the power switch to OFF and then ON.
    2. Check the connection of the Fixing Assembly. (Connection error of the Drawer, connector disconnection, open circuit)
    3. Check the connection between the AC Driver PCB (PCB4) and Fixing Assembly.
    4. Replace the Fixing Assembly.
    5. Replace the AC Driver PCB (PCB4).
    6. Replace the DC Controller PCB (PCB1).
  • Code: E003-0000
  • Description: Fixing Assembly temperature decrease error (during printing)
    1. The Fixing Main Thermistor (THM1) detected the temperature of lower than 80 degrees C for 200msec or longer on end.
    2. The Fixing Sub Thermistor (THM2) detected the temperature of lower than 60 degrees C for 200msec or longer on end.
  • Remedy: 1. Perform the following to clear the error: COPIER > FUNCTION > CLEAR > ERR in the Service Mode; then, turn the power switch to OFF and then ON.
    2. Check the connection of the Fixing Assembly. (Connection error of the Drawer, connector disconnection, open circuit)
    3. Check the connection between the AC Driver PCB (PCB4) and Fixing Assembly.
    4. Replace the Fixing Assembly.
    5. Replace the AC Driver PCB (PCB4).
    6. Replace the DC Controller PCB (PCB1).
  • Code: E004-0000
  • Description: Thermistor disconnection detection error
    The disconnection of the thermistor connector was detected for 30msec on end.
  • Remedy: 1. Check the connection of the Fixing Assembly. (Connection error of the Drawer, connector disconnection, open circuit)
    2. Check the connection between the AC Driver PCB (PCB4) and Fixing Assembly.
    3. Replace the Fixing Assembly.
    4. Replace the AC Driver PCB (PCB4).
    5. Replace the DC Controller PCB (PCB1).
  • Code: E010-0001
  • Description: Main Motor (M2) rotation error
    The lock signal was not detected for 2.0 seconds while detecting the signal every 100msec since starting the drive of the motor.
  • Remedy: 1. Check the connector connection between the Main Motor (M2) and the DC Controller PCB (PCB1).
    2. Replace the Main Motor (M2).
    3. Replace the DC Controller PCB (PCB1).