Mã lỗi 100-0302-05 — Canon iR Advance C5540i

Code: 100-0302-05

Description: Laser Scanner error
Causes: Correction in timing of laser exposure to the Polygon Mirror (C, Bk) was not completed within the specified period of time.
Remedy: [Related parts] R1.00 - Small-diameter Coaxial Cable connecting from the Riser PCB (J9) to the Laser Driver PCB (C) and (Bk) (UN15/J802 and UN14/J822) - Connector between the Main Controller PCB and the Riser PCB - Harness between the DC Controller PCB (UN1/J171) and the Laser Driver PCB (C) (UN15/J862) - Laser Driver PCB (C) (UN15) - Laser Driver PCB (Bk) (UN14) - Main Controller PCB - Riser PCB - DC Controller PCB (UN1) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES