Code: 713-0021-05
Description: Finisher communication error
Causes: Reception incomplete was detected consecutively in communication between the host machine and the finisher.
Remedy: a. STAPLE/BOOKLET FINISHER-Y1 [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN1/J110), the Relay Path Unit and the Finisher Controller PCB - Harnesses connecting the Relay PCB (UN5/J403), the Relay Path Unit and the Finisher Controller PCB - DC Controller PCB (UN1) - Relay PCB (UN5) - Relay Path Unit - Finisher Controller PCB b. INNER FINISHER-H1 [Related parts] - Harness between the DC Controller PCB (UN1/J110) and the Finisher Controller PCB - Harness between the Relay PCB (UN5/J403) and the Finisher Controller PCB - DC Controller PCB (UN1) - Relay PCB (UN5) - Finisher Controller PCB [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES - After replacement of the Finisher Controller PCB, refer to "Adjustments> Adjustment when Replacing the Parts" in the Service Manual for the Finisher.