Code: 002-0001-05
Description: Fixing Thermistor low temperature detection error
Causes: After the Fixing Heater was turned ON, the Fixing Film Unit Main Thermistor detected no temperature increase.
Remedy: [Related parts] R1.00 - Harness between the Pickup Driver PCB (UN4/J1489) and the IH Power Supply PCB (UN30/ J501) - Harnesses connecting the IH Power Supply PCB (UN30/J510), the Drawer Unit (J8027) and the Main Heater (H4) - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 1 (THM11/J7404) - Main Heater (H4) - Fixing Film Unit - IH Power Supply PCB (UN30) - Pickup Driver PCB (UN4) [Remedy] Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR.