Description: Fixing Thermistor high temperature detection error
Causes: The Fixing Film Unit Main Thermistor detected an abnormally high temperature.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 1 (THM11/J7404) - Fixing Film Unit - Pickup Driver PCB (UN4) [Remedy] Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. 1. Check the harness between the Pickup Driver PCB and the Fixing Film Unit Main Thermistor. 2. Pull out the Fixing Feed Unit and check "FIX-UC". a. In the case of below 240 deg C, replace the Fixing Film Unit. b. In the case of 240 deg C or higher, disconnect the connector of the Pickup Driver PCB and then check "FIX-UC" again. b-a. In the case of below 240 deg C, replace the harness between the Pickup Driver PCB and the Drawer Unit. b-b. In the case of 240 deg C or higher, replace the Pickup Driver PCB.
Description: Fixing Thermistor high temperature detection error
Causes: The Fixing Film Unit Sub Thermistor 1 detected an abnormally high temperature.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 2 (THM13/J8003) - Fixing Film Unit - Pickup Driver PCB (UN4) [Remedy] Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. 1. Check the harness between the Pickup Driver PCB and the Fixing Film Unit Sub Thermistor 1. 2. Pull out the Fixing Feed Unit and check "FIX-UC". a. In the case of below 240 deg C, replace the Fixing Film Unit. b. In the case of 240 deg C or higher, disconnect the connector of the Pickup Driver PCB and then check "FIX-UC" again. b-a. In the case of below 240 deg C, replace the harness between the Pickup Driver PCB and the Drawer Unit. b-b. In the case of 240 deg C or higher, replace the Pickup Driver PCB.
Description: Fixing Thermistor high temperature detection error
Causes: The Fixing Film Unit Sub Thermistor 2 detected an abnormally high temperature.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 2 (THM13/J8003) - Fixing Film Unit - Pickup Driver PCB (UN4) [Remedy] Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. 1. Check the harness between the Pickup Driver PCB and the Fixing Film Unit Sub Thermistor 2. 2. Pull out the Fixing Feed Unit and check "FIX-UC". a. In the case of below 240 deg C, replace the Fixing Film Unit. b. In the case of 240 deg C or higher, disconnect the connector of the Pickup Driver PCB and then check "FIX-UC" again. b-a. In the case of below 240 deg C, replace the harness between the Pickup Driver PCB and the Drawer Unit. b-b. In the case of 240 deg C or higher, replace the Pickup Driver PCB.
Description: Fixing Thermistor high temperature detection error
Causes: The Fixing Film Unit Main Thermistor detected an abnormally high temperature.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 1 (THM11/J7404) - Fixing Film Unit - Pickup Driver PCB (UN4) [Remedy] Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. 1. Check the harness between the Pickup Driver PCB and the Fixing Film Unit Main Thermistor. 2. Pull out the Fixing Feed Unit and check "FIX-UC". a. In the case of below 240 deg C, replace the Fixing Film Unit. b. In the case of 240 deg C or higher, disconnect the connector of the Pickup Driver PCB and then check "FIX-UC" again. b-a. In the case of below 240 deg C, replace the harness between the Pickup Driver PCB and the Drawer Unit. b-b. In the case of 240 deg C or higher, replace the Pickup Driver PCB.
Description: Fixing Thermistor high temperature detection error
Causes: The Fixing Film Unit Sub Thermistor 1 detected an abnormally high temperature.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 2 (THM13/J8003) - Fixing Film Unit - Pickup Driver PCB (UN4) [Remedy] Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. 1. Check the harness between the Pickup Driver PCB and the Fixing Film Unit Sub Thermistor 1. 2. Pull out the Fixing Feed Unit and check "FIX-UC". a. In the case of below 240 deg C, replace the Fixing Film Unit. b. In the case of 240 deg C or higher, disconnect the connector of the Pickup Driver PCB and then check "FIX-UC" again. b-a. In the case of below 240 deg C, replace the harness between the Pickup Driver PCB and the Drawer Unit. b-b. In the case of 240 deg C or higher, replace the Pickup Driver PCB.
Description: Fixing Thermistor high temperature detection error
Causes: The Fixing Film Unit Sub Thermistor 2 detected an abnormally high temperature.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 2 (THM13/J8003) - Fixing Film Unit - Pickup Driver PCB (UN4) [Remedy] Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. 1. Check the harness between the Pickup Driver PCB and the Fixing Film Unit Sub Thermistor 2. 2. Pull out the Fixing Feed Unit and check "FIX-UC". a. In the case of below 240 deg C, replace the Fixing Film Unit. b. In the case of 240 deg C or higher, disconnect the connector of the Pickup Driver PCB and then check "FIX-UC" again. b-a. In the case of below 240 deg C, replace the harness between the Pickup Driver PCB and the Drawer Unit. b-b. In the case of 240 deg C or higher, replace the Pickup Driver PCB.
Description: Fixing Thermistor high temperature detection error
Causes: The Fixing Film Unit Thermistor (Rear) detected an abnormally high temperature.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 2 (THM13/J8003) - Fixing Film Unit - Pickup Driver PCB (UN4) [Remedy] Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. 1. Check the harness between the Pickup Driver PCB and the Fixing Film Unit Thermistor (Rear). 2. Pull out the Fixing Feed Unit and check "FIX-UC". a. In the case of below 240 deg C, replace the Fixing Film Unit. b. In the case of 240 deg C or higher, disconnect the connector of the Pickup Driver PCB and then check "FIX-UC" again. b-a. In the case of below 240 deg C, replace the harness between the Pickup Driver PCB and the Drawer Unit. b-b. In the case of 240 deg C or higher, replace the Pickup Driver PCB.
Description: Fixing Thermistor high temperature detection error
Causes: The Fixing Film Unit Thermistor (Front) detected an abnormally high temperature.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 1 (THM11/J7404) - Fixing Film Unit - Pickup Driver PCB (UN4) [Remedy] Perform the following in the order while checking whether the error is cleared. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR. 1. Check the harness between the Pickup Driver PCB and the Fixing Film Unit Thermistor (Front). 2. Pull out the Fixing Feed Unit and check "FIX-UC". a. In the case of below 240 deg C, replace the Fixing Film Unit. b. In the case of 240 deg C or higher, disconnect the connector of the Pickup Driver PCB and then check "FIX-UC" again. b-a. In the case of below 240 deg C, replace the harness between the Pickup Driver PCB and the Drawer Unit. b-b. In the case of 240 deg C or higher, replace the Pickup Driver PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.