Mã lỗi 004-0214-05 — Canon iR Advance C7580i

Code: 004-0214-05

Description: Protection circuit error
Causes: It was detected that temperature difference between the Fixing Film Unit Thermistor (Front) and the Fixing Film Unit Thermistor (Rear) was 50 deg C or more.
Remedy: [Related parts] R1.00 - Harnesses connecting the Pickup Driver PCB (UN4/J1491), the Drawer Unit (J8001) and the Fixing Thermistor Unit 1/2 (THM11/J7404 and THM13/J8003) - Harness between the Relay PCB (UN7/J1816) and the Fixing Motor (M48/J7612) - Fixing Film Unit - Fixing Motor (M48) - Pickup Driver PCB (UN4) - Relay PCB (UN7) [Remedy] Check/replace the related harness/cable, connector and parts. After performing the remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR.