Code: 012-0503-05
Description: ITB speed detection error
Causes: The ITB Drive Roller Speed Detection PCB 2 detected a rotation signal error.
Remedy: [Related parts] R1.00 - Harnesses connecting from the DC Controller PCB (UN2/J1242) to the Drawer Unit (J8050) to the ITB Drive Roller Speed Detection PCB 2 and ITB Drive Motor (UN17/J7319 and M3/J7518) - ITB Drive Roller Speed Detection PCB 2 (UN17) - ITB Drive Motor (M3) - Drum Unit (C, M, Y, Bk) - DC Controller PCB (UN2) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Clean the ITB Drive Roller Speed Detection PCB 2. 2. Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES