Mã lỗi 025-0150-05 — Canon iR Advance C7580i

Code: 025-0150-05

Description: Toner Density Sensor (Y) output lower limit error
Causes: The Toner Density Sensor (Y) detected that the output (Vsig_ind) was 51 or less 10 consecutive times.
Remedy: [Related parts] R1.00 - Harness between the Side Driver PCB (UN96/J1305) and the Toner Density Sensor (Y) (TS2/ J8944) - Harness between the DC Controller PCB (UN2/J1247) and the Hopper and Stirring Supply Motor (Y) (M9/J7104) - Toner Density Sensor (Y) (TS2) - Hopper and Stirring Supply Motor (Y) (M9) - Hopper Unit (Y) - Side Driver PCB (UN96) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES