Code: 505-0001-02
Description: a. Finisher back-up RAM (EEPROM) error (Finisher-X1) b. Finisher data error (Finisher-V) c. Backup data error (failed data reading) (Document Insertion Unit-N1; Location Inf. 71)
Causes: a. The checksum for the EEPROM data has an error. (The value written in EEPROM and the value extracted from EEPROM doesn't conform.) b. The data read from Finisher Controller PCB has an error. (The read data doesn't match with the written data.) c. Data failed to be read properly
Remedy: a. STAPLE FIN-X1/BOOKLET FIN-X1 [Remedy] Check/replace the Finisher Controller PCB (PBA101). [Reference] When replacing the Finisher Controller PCB, refer to "Adjustment> Action on parts replacement" in the Service Manual. b. STAPLE FIN-V/BOOKLET FIN-V [Related parts] - Finisher Controller PCB (PCB101) [Remedy] Replace the Finisher Controller PCB. [Reference] When replacing the Finisher Controller PCB, refer to "Adjustment> When Replacing the Parts" in the Service Manual. c. INSERTION UNIT-N1 [Related parts] - Insertion Unit Controller PCB (PCB3) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - When replacing the Insertion Unit Controller PCB, refer to "Adjustments> Adjustment when Replacing the Parts" in the Service Manual.