Code: 562-8004-02
Description: a. Error in the Upper Stopper HP Sensor (Paper Folding Unit-J1) b. Error in Upper Stopper Sensor (Document Insertion / Folding Unit-K1)
Causes: a. The receiving-light intensity is not within the threshold while the emitting-light intensity is adjusted within the threshold at the sensor adjusment. b. The light-receiving amount of the Upper Stopper Sensor was not within the threshold level although the light-emitting amount of the sensor was adjusted to be within the threshold level.
Remedy: a. Paper Folding Unit-J1 [Related parts] -Harnesses from the Paper Folding Unit Controller PCB to the Upper Stopper HP Sensor (S23). -Upper Stopper HP Sensor (S23) -Paper Folding Unit Controller PCB (PCB1) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] When replacing the Paper Folding Unit Controller PCB, refer to "Adjustments> Adjustment when Replacing the Parts" in the Service Manual. b. Document Insertion / Folding Unit-K1 [Related parts] - Harnesses from the Inserter/Folder ContRoller PCB (PCB2) to the Upper Stopper Sensor (S16) - Inserter/Folder ContRoller PCB (PCB2) - Upper Stopper Sensor (S16) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - When replacing the Inserter/Folder ContRoller PCB, refer to "Adjustments> Adjustment when Replacing the Parts" in the Service Manual.